STANDARD CONSTRUCTION DRAWINGS

TITLE OF DRAWING DRAWING NUMBER DRAWING DATE REVISION DATE
Drainage      
Drain Tile Replacement D-1 10-24-85  
Cradle Type Headwall for Concrete Pipe D-2 10-09-86 06-21-07
Channel Protection for Headwall D-3 10-09-86  
Spring Drain Detail D-4 11-21-86 09-10-97
Headwall No. 1 D-5 07-28-87  
Sediment Control Silt Fence D-6 08-01-91 08-23-93
Temporary Sediment Barrier Straw or Hay Bales D-7 06-08-93  
Erosion Control (Sediment Barriers in Drainage Ways) D-8 08-19-93  
Construction Entrance for Erosion and Sediment Control D-9 06-08-93  
Erosion Control Storm Drain Inlet Protection (3 pages) D-10 08-09-93 09-13-93
Erosion Control Notes (2 pages) D-11 08-19-93  
Ditch Enclosure Detail D-12 03-17-99  
Ditch Enclosure Reference ( Fairfield County)      
Ditch Culvert Detail D-13 03-17-99  
Complete Set of Drainage Drawings D    
       
Miscellaneous      
Bike Path Wood Bollard Detail M-2 01-28-88  
Removable Bollard Detail M-3 01-28-88  
Specifications for Dumpster Enclosure (3 pages) M-4 04-03-95 12-22-97
Mailbox Installation (2 pages)                                         VOID M-5 03-17-99 VOID
Downtown Pedestrian Crosswalk Markings M-6 09-06-00  
Project Identification Sign M-7 03-23-05  
Complete Set of Miscellaneous Drawings M    
       
Pavement/Sidewalks      
Typical Pavement Replacement for Trenches, Alleys & Drives (3 Pages) P-1 12-23-85 06-21-07
Typical Pavement and Utility Cut Repair Standards  P-2 04-28-94 01-22-01
Typical Curb and Gutter     (2 Pages) P-3 09-27-91 02-20-01
Typical Pavement Feathering  P-4 06-01-82 02-02-10
Typical Construction for Manhole Casting Adjustment P-5 06-01-82 02-02-10
Typical Straight Curb (Item 609)  P-6 12-11-91 02-02-10
Portland Cement Concrete Sidewalk (Item 608) (2 Pages) P-7 03-23-84 02-02-10

Typical Curb Ramp Standards                                       VOID

P-8 06-18-03 04-21-10
         Curb Ramps (ODOT Specs. BP-7.1) 04-16-10      
Typical Alley Section   P-9 05-20-86  
Typical Alley Intersection with Straight Curb P-10 05-23-86  
Typical Alley Intersection with Curb and Gutter P-11 05-23-86  
Joint Details for Portland Cement Concrete Paving P-12 05-27-86  
Resurfacing End Feather Details P-13 04-26-90  
Resurfacing Gutter Feathering Details P-14 04-26-90  
Resurfacing Miscellaneous Details    P-15 05-14-93  
Resurfacing at Structure Details P-16 05-14-93  
Pavement Widening Details P-17 04-26-90  
Resurfacing Partial Width Pavement Planning P-18 05-14-93  
Drive Approach Notes P-20 08-09-93  
Driveway and Mailbox Apron Detail   11-09-98  
Residential Drive Approach for Curbed Streets P-21 10-29-90 02-02-10
Pipe Roof Drain (Item 618) P-22 09-13-96 02-02-10

Standard Driveway (Commercial) on Public R/W and Specifications (Non Arterial Street)          

P-23 11-13-97 02-02-10
Typical Street Connection P-24 11-06-00  
Temporary Pavement Replacement P-25 11-02-00  
Typical Utility Excavation Plan Detail Requirements (2 Pages) P-26 12-16-08 03-04-09
Backfilling Within Highway Right-Of-Way P-27 03-04-09  
Complete Set of Pavement/Sidewalk Drawings P    
       
Sewer Line      
Type 1 Bedding for Sewer Pipe 6”-27” Diameter (Item 901) S-1 12-23-85 06-21-07
Stone Foundation for 6” to 108” Diameter Pipe (Item 906) S-2 05-05-86 02-14-05
Type 1 Bedding for Sewer Pipe 30”-108” Diameter (Item 901) S-3 05-05-86  
Type II Bedding for Sewer Pipe 30”-108” Diameter (Item 901) S-4 05-05-86  
Typical Trench Detail for Storm Sewers Outside R/W with Cover 30” or Less S-5 05-05-86  
Manhole Standard No. 1 Precast Base 8” thru 27’ Pipe S-6 11-06-81 11-13-97
Type “2” Manhole 60” Precast Base 30” Thru 42” Pipe S-7 11-06-81 06-21-07
Type “3” Manhole Precast Base 48” Diameter & Larger (2 Pages) S-8 04-28-86 06-21-07
Type “4” Manhole Cast-In-Place Base S-9 04-28-86 06-21-07
Cast In Place Concrete Slab For Shallow Manholes S-10 05-05-86 06-21-07
Standard Dimensions For Manhole Frame & Cover Casting (Sanitary Sewers ) S-11 10-23-85 06-21-07
Standard Dimensions For Manhole Frame & Cover Casting (Storm Sewers) S-12 10-24-85 06-21-07
Typical Manhole Step S-13 11-06-81 06-21-07
Curb and Gutter Inlet (2 Pages) S-14 07-31-98 06-21-07
Miscellaneous Items  - Precast Manholes S-15 09-24-85 06-21-07
Typical Assembly Combinations for Precast Manholes S-16 09-24-85 06-21-07
Inside Drop & Outside Drop Pipe For Manholes S-17 10-20-85 06-21-07
Typical Cleanout and Cleanout Stopper For Lawn Areas S-18 10-10-86  
Typical Wye Type Riser (For Sewers 27” and Under) and Typical Cleanout AA-S161 12-15-93  
Typical Cleanout and Lamphole Casting For Pavement Areas S-19 10-10-86  
Typical Sanitary House Connection Service (2 Pages) S-20 10-30-00 02-14-05
Typical Tee Type Riser (For Sewers 30” & Over) S-21 05-05-86  
Service Connection For Existing Sanitary Sewer Pipe S-22 08-04-87  
12” Pipe Inlet   S-23 07-27-87  
Trench Dam Concrete                                                      VOID S-24 12-1999 VOID
Curb and Gutter Inlet Double Unit (2 Pages) S-25 04-10-97 06-21-07
Precast Manhole Base Channelization Detail S-26 11-13-97  
Alternate Combined Inlet (2 Pages) S-27 06-21-07  
Encasement Detail 6"-108" Diameter Item 901 S-28 06-21-07  
       
Traffic Control      
Street Sign Installation Standards (3 Pages) TC-1 12-10-07 02-25-09
       
Water      
Typical Trench for Water Lines W-1    
Typical Pavement Replacement for Trenches W-1B    
Typical Pavement Replacement for Trenches W-1C    
Standard Water Service W-2    
Water Service Extension and Curb Box Relocation W-3    
Typical Hydrant Setting Type "A" W-4    
Typical Hydrant Setting Type "A" Modified W-5    
Standard Slide Type Water Value Box W-10    
Typical Water Line Lowering W-12    
Casing Pipe Plugging W-13    
End of Pipe Thrust Block Detail W-15    
Typical Air Release 3/4" or 1" W-16    
Concrete Value Support W-19    
Backing for Bends W-20    
Typical 4" or Larger Tee and Value Setting and Backing for Tees W-21    
Typical Hydrant Setting Type "C" and Type "C" Modified W-22    
Cold Weather Indoor/Above Ground Installation of High Hazard Backflow Preventer and Meter Set W-23    
Standard Low-Medium Meter/Backflow Preventer Set W-24    
Standard Residential Below Ground Meter Set & Backflow Preventer W-25    
Typical Commercial 3/4" & 1" Fire Line with Domestic Water Service with Meter/Backflow Preventer Set W-25A    
Standard Medium Hazard "Y" Strainer/Meter/Backflow Preventer Set with Fire Line W-25B    
Standard High Hazard "Y" Strainer/Meter/Backflow Preventer Set with Fire Line W-25C    
4", 6", 8" & 12" Residential Meter Pit Set W-25D    
Typical Domestic Water Service with High Hazard Backflow Preventer Set for Irrigation Line W-25E    
Typical 4" to 16" Fire Line Connection Type "A" W-26    
Typical 4" to 16" Fire Line Connection Type "B" W-27    
Typical Water Service 1/2" to 2" W-28    
Typical Underground Service Line Tunnel and Typical Underground Service Line W-31    
Standard Outside Meter Set for 5/8", 3/4" and 1" Meters/Backflow Preventers W-32    
       

 